Laird Thermal Systems
UltraTEC™ UT Series UT15-200-F2-4040-TA-W6
MFG Part Number: 430856-500
Legacy Product
UltraTEC™ UT Series Thermoelectric Cooler
Note: This product is not recommended for new designs.
The recommended replacement is:
      MFG Part Number: 387004711
      Description: UTX15-200-F2-4040-TA-W6

The UT15-200-F2-4040-TA-W6 is a high heat flux density thermoelectric cooler. The thermoelectric module is assembled with a large number of semiconducting thermoelectric couples to achieve a higher heat pumping capacity than standard single stage thermoelectric coolers. It has a maximum Qc of 193.4 Watts when ΔT = 0 and a maximum ΔT of 68.9 °C at Qc = 0.
Features
  • High heat pump density
  • Precise temperature control
  • Reliable solid-state operation
  • No sound or vibration
  • DC operation
  • RoHS-compliant

Electrical and Thermal Performance

For maximum performance, be sure to orient the CONTROL side of the TEC against the application to be managed and the AMBIENT side against the heat sink or other heat rejection method. The CONTROL side is always opposite the side with lead attachments. Lead attachment is a passive heat loss and less impactful if located on the side that attaches to the heat exchanger.


Laird Thermal Systems
UltraTEC™ UT Series UT15-200-F2-4040-TA-W6
MFG Part Number: 430856-500
Legacy Product

Laird Thermal Systems
UltraTEC™ UT Series UT15-200-F2-4040-TA-W6
MFG Part Number: 430856-500
Legacy Product
Specifications
Hot Side Temperature
27.0 °C
35.0 °C
50.0 °C
Qcmax (ΔT = 0)
193.4 Watts
199.3 Watts
209.7 Watts
ΔTmax (Qc = 0)
68.9°C
71.8°C
77.0°C
Imax (I @ ΔTmax)
15.2 Amps
15.1 Amps
14.9 Amps
Vmax (V @ ΔTmax)
21.5 Volts
22.3 Volts
23.8 Volts
Module Resistance
1.32 Ohms
1.38 Ohms
1.48 Ohms
Max Operating Temperature
80 °C
 
 
Weight
36.0 gram(s)
 
 

Finishing Options
Suffix
Thickness
Flatness / Parallelism
Hot Face
Cold Face
Lead Length
 TA
3.300 ±0.025 mm
0.130 ± 0.0010 in
0.025 mm / 0.025 mm
0.001 in / 0.001 in
Lapped
Lapped
152.4 mm
6.00 in

Sealing Options
Suffix
Sealant
Color
Temp Range
Description
 
None
No sealing specified

Notes
  1.  Max operating temperature: 80°C
  2.  Do not exceed Imax or Vmax when operating module
  3.  Reference assembly guidelines for recommended installation

Any information furnished by Laird and its agents, whether in specifications, data sheets, product catalogues or otherwise, is believed to be (but is not warranted as being) accurate and reliable, is provided for information only and does not form part of any contract with Laird. All specifications are subject to change without notice. Laird assumes no responsibility and disclaims all liability for losses or damages resulting from use of or reliance on this information. All Laird products are sold subject to the Laird Terms and Conditions of sale (including Laird’s limited warranty) in effect from time to time, a copy of which will be furnished upon request.