DL-120-24-00
MFG Part Number DL-120-24-00-00-00
Liquid Series Thermoelectric Cooler Assembly
The DL-120-24-00 thermoelectric cooler assembly offers dependable, compact performance by cooling objects via liquid to transfer heat. Heat is absorbed through a cold block and dissipated thru a second liquid heat exchanger. The thermoelectric modules are custom designed to achieve a high coefficient of performance (COP) to minimize power consumption. It has a maximum Qc of 135 Watts when ΔT = 0 and a maximum ΔT of 42 °C at Qc = 0. The liquid heat exchanger is designed to accommodate distilled water with glycol. Corrosion resistant turbulators are enclosed inside channels to increase heat transfer. Mating port adaptors are sold separately.
Features
  • Compact design
  • Precise temperature control
  • Reliable solid-state operation
  • DC operation
  • RoHS-compliant

You can interact with the Performance Curves below to estimate the cooling performance by entering the thermal and electrical operating conditions for your application.
Click the [Custom Datasheet] button to create a Customized PDF Datasheet.
Please Note: Actual application performance will vary from calculated values based on actual thermal design characteristics.





Electrical and Thermal Performance

Use the sliders, input fields and [UPDATE] button below to enter your application's electrical and thermal conditions. Use the Graph Y and X Axis buttons to display a variety of performance curves and use the Voltage/Current slider to choose the electrical operating point to display performance.
Click [Custom Datasheet] button to save your results as a Customized PDF Datasheet.


Select Graph
Y - Axis




Select Graph
X - Axis




System Resistance


Optimum COP
Cooling Power (Qc) = 32.99 Watts
TEM Voltage = 12.92 Volts
TEM Current = 2.13 Amps
TEM COP = 1.20
Power Supply = 27.6 Watts
Power Dissipated (Qh) = 60.55 Watts
Maximum Qc
Cooling Power (Qc) = 91.15 Watts
TEM Voltage = 28.12 Volts
TEM Current = 4.89 Amps
TEM COP = 0.66
Power Supply = 137.4 Watts
Power Dissipated (Qh) = 228.6 Watts

Electrical Operating Point
Imin: 1.1 A
Imax: 4.9 A

Vmin: 7.6 V
Vmax: 28.1 V
TEC Voltage

TEC Current
Cooling Power (Qc)

Power Supply (Pin)

TEC COP (Qc/Pin)

Power Dissipated (Qh)

Thermal Operating Conditions
 Cooling 
 Heating  
Ambient High Temperature
Control Temperature
Ambient Low Temperature
Cooling ΔT
Heating ΔT
Click to UPDATE performance after changing thermal operating conditions or switching between heating and cooling mode.

Specifications
Heat Transfer Mechanism, Cold Side
Direct - Conduction
Heat Transfer Mechanism, Hot Side
Liquid - Forced Convection
Operating Temperature Range
-40°C to 62°C
Supply Voltage
24.0 VDC nominal / 28.0 VDC maximum
Current Draw
4.1 A running / 4.7 A startup
Power Supply
98.4 Watts
Performance Tolerance
10%
Hi-Pot Testing
750 VDC
Over-Temp Thermostat (Hot and Cold Side Heat Sink)
75°C ±5°C (hot side heat sink)
Weight
0.70 kg
Panel Mounting
Flush Mount

Mounting Hole Location
Electrical Connections

Notes
1Cold block requires insulation to minimize moisture buildup under dew point conditions.

Any information furnished by Laird and its agents, whether in specifications, data sheets, product catalogues or otherwise, is believed to be (but is not warranted as being) accurate and reliable, is provided for information only and does not form part of any contract with Laird. All specifications are subject to change without notice. Laird assumes no responsibility and disclaims all liability for losses or damages resulting from use of or reliance on this information. All Laird products are sold subject to the Laird Terms and Conditions of sale (including Laird’s limited warranty) in effect from time to time, a copy of which will be furnished upon request.

© Copyright 2019-2024 Laird Thermal Systems, Inc. All rights reserved. Laird™, the Laird Ring Logo, and Laird Thermal Systems™ are trademarks or registered trademarks of Laird Limited or its subsidiaries.

Revision: 00 Date: 06-01-2022

Print Date: 11-24-2024