Laird Thermal Systems
SuperCool Series SLA-205-24-02
MFG Part Number: 387000639
Legacy Product
SuperCool Series Thermoelectric Cooler Assembly
Note: This product is not recommended for new designs.
Please use the recommended replacement:

      MFG Part Number: 387006704
      Description: SLAX-215-24-02

The SLA-205-24-02 Liquid-to-Air thermoelectric cooler assembly is a high performance thermoelectric based liquid cooler. It is designed to temperature control small chambers used in medical diagnostics, lasers, imaging systems or sample storage compartments in analytical instrumentation. This unique, patented design offers a high performance hot side heat dissipation mechanism that convects heat more efficiently than conventional heat exchanger technologies. The design utilizes custom next-generation high-performance thermoelectric modules to maximize cooling capacity and premium grade fans to keep the noise down. Moisture resistant insulation is used to keep condensation from penetrating into the thermoelectric module cavity. This unit operates at 24 VDC and is designed for indoor lab use environment. It has a maximum Qc of 202 Watts when ΔT = 0 and a maximum ΔT of 40 °C at Qc = 0.
US Patent US2016/0255746 A1






Electrical and Thermal Performance

Laird Thermal Systems
SuperCool Series SLA-205-24-02
MFG Part Number: 387000639
Legacy Product

Laird Thermal Systems
SuperCool Series SLA-205-24-02
MFG Part Number: 387000639
Legacy Product
Specifications
Heat Transfer Mechanism, Cold Side
Liquid - Forced Convection
Heat Transfer Mechanism, Hot Side
Air - Forced Convection
Operating Temperature Range
-20°C to 60°C
Supply Voltage
24.0 VDC nominal / 28.0 VDC maximum
Current Draw
7.4 A running / 8.6 A startup
Power Supply
206.0 Watts
Performance Tolerance
10%
Hi-Pot Testing
750 VDC
Fan MTBF
50000 hours
Sound Level (1 m distance)
63 dBA
Weight
4.10 kg
Panel Mounting
Through

Laird Thermal Systems
SuperCool Series SLA-205-24-02
MFG Part Number: 387000639
Legacy Product
Mounting Hole Location
Wiring Schematic

Notes
1For indoor use only
2Units are generally maintenance free, however occasionally it is recommended to clean the heat sinks and fans of debris. This is best done with compressed air.

Any information furnished by Laird and its agents, whether in specifications, data sheets, product catalogues or otherwise, is believed to be (but is not warranted as being) accurate and reliable, is provided for information only and does not form part of any contract with Laird. All specifications are subject to change without notice. Laird assumes no responsibility and disclaims all liability for losses or damages resulting from use of or reliance on this information. All Laird products are sold subject to the Laird Terms and Conditions of sale (including Laird’s limited warranty) in effect from time to time, a copy of which will be furnished upon request.

© Copyright 2019-2024 Laird Thermal Systems, Inc. All rights reserved. Laird™, the Laird Ring Logo, and Laird Thermal Systems™ are trademarks or registered trademarks of Laird Limited or its subsidiaries.

Revision: 00 Date: 06-01-2022

Print Date: 11-21-2024