Refrigeration Systems for Reagent Storage

Introduction

Reagents are essential for laboratory and medical testing. Reagent materials are used to detect the presence or absence of a substance, or to test if a specific reaction occurs. Thermal control is vital to preserve reagent materials, which can degrade over time when stored at improper temperatures. When they are kept at room temperature, reagents may become contaminated by microbial growth, which affects test integrity. Reagents can also be negatively affected at low temperatures if they undergo multiple freeze-thaw cycles. 




Download PDF:


MS5-257-10-15-00-W8

The MS5-257-10-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 2 Watts when ΔT = 0 and a maximum ΔT of 129 °C at Qc = 0.


Qc Max:


MS4-129-10-15-22-W8

The MS4-129-10-15-22-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 1.8 Watts when ΔT = 0 and a maximum ΔT of 120 °C at Qc = 0.


Qc Max:


MS4-129-10-15-00-W8

The MS4-129-10-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 1.8 Watts when ΔT = 0 and a maximum ΔT of 120 °C at Qc = 0.


Qc Max:


MS4-115-14-15-00-W8

The MS4-115-14-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 2.8 Watts when ΔT = 0 and a maximum ΔT of 124 °C at Qc = 0.


Qc Max:


MS4-108-10-20-00-W8

The MS4-108-10-20-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 1.1 Watts when ΔT = 0 and a maximum ΔT of 120 °C at Qc = 0.


Qc Max:


MS3-231-10-15-22-RT-W8

The MS3-231-10-15-22-RT-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 6.7 Watts when ΔT = 0 and a maximum ΔT of 106 °C at Qc = 0.


Qc Max:


MS3-231-10-15-22-EP-W8

The MS3-231-10-15-22-EP-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 6.7 Watts when ΔT = 0 and a maximum ΔT of 106 °C at Qc = 0.


Qc Max:


MS3-231-10-15-00-W8

The MS3-231-10-15-00-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 6.7 Watts when ΔT = 0 and a maximum ΔT of 106 °C at Qc = 0.


Qc Max:


MS3-119-20-15-22-W8

The MS3-119-20-15-22-W8 multistage thermoelectric cooler is able to reach colder temperatures than single stage thermoelectric coolers. It has a maximum Qc of 14 Watts when ΔT = 0 and a maximum ΔT of 106 °C at Qc = 0.


Qc Max: